Tools

This page documents the 79 MCP tools the server exposes. Tools are registered under the rs-cmw500 namespace when the server is loaded by an MCP client.

Tool index

Connection (6)

Tool Purpose
cmw_discover Scan for CMW500 instruments on the network
cmw_connect Connect to CMW500 at host:port
cmw_disconnect Disconnect from CMW500
cmw_identify Get instrument ID (*IDN?)
cmw_get_status Get connection and configuration status
cmw_query_options Query installed hardware/software options

GPRF Generator (7)

Tool Purpose
cmw_gen_set_frequency Set output frequency (Hz)
cmw_gen_set_level Set output level (dBm)
cmw_gen_output_on Enable RF output
cmw_gen_output_off Disable RF output
cmw_gen_load_arb Load ARB waveform file
cmw_gen_configure_arb Configure ARB playback mode
cmw_gen_set_baseband_mode Set baseband mode (CW / ARB)

GPRF Analyzer (10)

Tool Purpose
cmw_meas_set_frequency Set measurement frequency (Hz)
cmw_meas_set_expected_power Set expected input power (dBm)
cmw_meas_configure_power Configure power measurement
cmw_meas_configure_spectrum Configure spectrum measurement
cmw_meas_trigger Trigger power measurement
cmw_meas_fetch_power Fetch power results
cmw_meas_fetch_spectrum Fetch spectrum results
cmw_meas_set_trigger Set trigger source and threshold
cmw_meas_set_power_filter Set measurement filter
cmw_meas_set_user_margin Set user margin (dB)

GPRF Signal Path (4)

Tool Purpose
cmw_set_signal_path Set measurement signal path scenario
cmw_get_signal_path Get current signal path
cmw_set_port Set generator/analyzer RF port
cmw_system_all_off Turn off all generators and measurements

LTE Signaling (16)

Tool Purpose
cmw_lte_configure_cell Configure cell (band, BW, EARFCN, power)
cmw_lte_cell_on Start base-station emulation
cmw_lte_cell_off Turn off LTE cell
cmw_lte_configure_nas Configure NAS (MCC, MNC)
cmw_lte_configure_bearer Configure EPS bearer (APN, IP version)
cmw_lte_configure_cdrx Configure C-DRX
cmw_lte_get_connection_state Get UE connection state
cmw_lte_get_ue_info Get UE information
cmw_lte_meas_configure Configure measurements (stat count, repetition)
cmw_lte_meas_trigger Trigger multi-evaluation measurement
cmw_lte_meas_fetch_power Fetch TX power results
cmw_lte_meas_fetch_evm Fetch EVM results
cmw_lte_meas_fetch_aclr Fetch ACLR results
cmw_lte_meas_fetch_sem Fetch SEM results
cmw_lte_meas_fetch_frequency_error Fetch frequency error results
cmw_lte_meas_fetch_all Fetch all LTE results in one call

WLAN Non-Signaling (11)

Tool Purpose
cmw_wlan_configure Configure WLAN measurement (standard, BW, freq, power)
cmw_wlan_set_standard Set 802.11 standard (A/B/G/N/AC/AX)
cmw_wlan_set_bandwidth Set channel bandwidth (20/40/80/160 MHz)
cmw_wlan_set_frequency Set measurement frequency (Hz)
cmw_wlan_set_expected_power Set expected input power (dBm)
cmw_wlan_trigger Trigger measurement
cmw_wlan_fetch_power Fetch TX power results
cmw_wlan_fetch_evm Fetch EVM results
cmw_wlan_fetch_spectrum_flatness Fetch spectrum flatness results
cmw_wlan_fetch_frequency_error Fetch frequency error results
cmw_wlan_fetch_all Fetch all WLAN results in one call

Bluetooth / BLE Non-Signaling (11)

Tool Purpose
cmw_bt_configure Configure BT/BLE measurement
cmw_bt_set_technology Set technology (Classic / LE)
cmw_bt_set_ble_mode Set BLE PHY (1M / 2M / Coded S2 / S8)
cmw_bt_set_packet_type Set Classic packet type (DH1-DH5)
cmw_bt_set_frequency Set measurement frequency (Hz)
cmw_bt_set_expected_power Set expected input power (dBm)
cmw_bt_trigger Trigger measurement
cmw_bt_fetch_power Fetch TX power results
cmw_bt_fetch_modulation Fetch DEVM results
cmw_bt_fetch_frequency Fetch frequency offset / drift results
cmw_bt_fetch_all Fetch all BT results in one call

SCPI (4)

Tool Purpose
cmw_scpi_send Send raw SCPI command (guarded)
cmw_scpi_query Send SCPI query and return response (guarded)
cmw_reset Reset to defaults (*RST)
cmw_preset Full system preset

Templates (3)

Tool Purpose
cmw_list_templates List available measurement templates
cmw_load_template Load a template by name
cmw_apply_template Apply loaded template to CMW500

Available templates: lte_tx_power, gprf_power, nonsig_rx, wlan_tx, wlan_rx, ble_tx, ble_rx, bt_classic_tx.

State (3)

Tool Purpose
cmw_save_state Save current state to file
cmw_load_state Load and restore state from file
cmw_get_full_state Get current full configuration state

Limits (4)

Tool Purpose
cmw_define_limit Define a pass/fail limit
cmw_check_limits Check values against defined limits
cmw_list_limits List all defined limits
cmw_clear_limits Clear all limits

Source of truth