Input/Output mechanisms

Configuration

Server

This example shows that the Server (here RTU) gets configured with 32 output and 32 input registers as well as the communication settings. Both are saved as seperated arrays of two different objects inp and out. The rest of the configuration is for piControl.

{
    "GUID": 
    "id": "d
    "type": "VIRTUAL",
    "productType": "24578",
    "position": "64",
    "name": "ModbusRTU Server",
    "bmk": "ModbusRTU Server",
    "inpVariant": 0,
    "outVariant": 0,
    "comment": "ModbusRTU Server",
    "offset": 1237,
    "inp": {
        "0": [
            "Input_1_i05",
            "0",
            "16",
            "0",
            false,
            "0000",
            "",
            ""
        ],
  ...
        "31": [
            "Input_32",
            "0",
            "16",
            "62",
            false,
            "0031",
            "",
            ""
        ]
    },
    "out": {
        "0": [
            "Output_1_i05",
            "0",
            "16",
            "64",
            false,
            "0032",
            "",
            ""
        ],
...
        "31": [
            "Output_32",
            "0",
            "16",
            "126",
            false,
            "0063",
            "",
            ""
        ]
    },
    "mem": {
        "0": [
            "device_path",
            "/dev/ttyUSB0",
            "256",
            "128",
            false,
            "0064",
            "",
            ""
        ],
        "1": [
            "baud_rate",
            "19200",
            "32",
            "160",
            false,
            "0065",
            "",
            ""
        ],
        "2": [
            "parity",
            "1",
            "8",
            "164",
            false,
            "0066",
            "",
            ""
        ],
        "3": [
            "data_bits",
            "8",
            "8",
            "165",
            false,
            "0067",
            "",
            ""
        ],
        "4": [
            "stop_bits",
            "1",
            "8",
            "166",
            false,
            "0068",
            "",
            ""
        ],
        "5": [
            "modbus_address",
            "1",
            "8",
            "167",
            false,
            "0069",
            "",
            ""
        ]
    },
    "extend": {}
}

Client

The next example shows that the Client (here TCP) gets configured with 32 output and 32 input registers, 32 output and 32 input bits, modbus status resets (not mutable), actions status resets (mutable), client status reset, as well as the communication settings. The action status resets are meant to configure communication timeouts and communication pauses, which is poorly documented. Inputs of registers and bits are stored in a common array within the inp object. The similar out object holds the output registers and bits. The rest of the configuration is for piControl.

{
    "GUID": "4985b9e8-6ff8-8520-9a1c-a93a3bf5444a",
    "id": "device_ModbusTCPClient_20180122_1_1_001",
    "type": "VIRTUAL",
    "productType": "24579",
    "position": "65",
    "name": "ModbusTCP Client",
    "bmk": "ModbusTCP Client",
    "inpVariant": 0,
    "outVariant": 0,
    "comment": "ModbusTCP Client",
    "offset": 1405,
    "inp": {
        "0": [
            "Input_Word_1",
            "0",
            "16",
            "0",
            false,
            "0000",
            "",
            ""
        ],
...
        "31": [
            "Input_Word_32",
            "0",
            "16",
            "62",
            false,
            "0031",
            "",
            ""
        ],
        "32": [
            "Input_Bit_1",
            "0",
            "1",
            "64",
            false,
            "0032",
            "",
            "0"
...
        "63": [
            "Input_Bit_32",
            "0",
            "1",
            "64",
            false,
            "0063",
            "",
            "31"
        ],
        "64": [
            "Modbus_Action_Status_1",
            "255",
            "8",
            "68",
            false,
            "0064",
            "",
            ""
        ],
...
        "96": [
            "Modbus_Client_Status",
            "255",
            "8",
            "100",
            false,
            "0096",
            "",
            ""
        ]
    },
    "out": {
        "0": [
            "Output_Word_1",
            "0",
            "16",
            "101",
            false,
            "0097",
            "",
            ""
        ],
...
        "31": [
            "Output_Word_32",
            "0",
            "16",
            "163",
            false,
            "0128",
            "",
            ""
        ],
        "32": [
            "Output_Bit_1",
            "0",
            "1",
            "165",
            false,
            "0129",
            "",
            "0"
        ],
...
        ],
        "63": [
            "Output_Bit_32",
            "0",
            "1",
            "165",
            false,
            "0160",
            "",
            "31"
        ],
        "64": [
            "Action_Status_Reset_1",
            "0",
            "1",
            "169",
            false,
            "0161",
            "",
            "0"
        ],
...
        "95": [
            "Action_Status_Reset_32",
            "0",
            "1",
            "169",
            false,
            "0192",
            "",
            "31"
        ],
        "96": [
            "Client_Status_Reset",
            "0",
            "8",
            "173",
            false,
            "0193",
            "",
            ""
        ]
    },
    "mem": {
        "0": [
            "server_IP_address",
            "192.168.0.10",
            "128",
            "174",
            false,
            "0194",
            "",
            ""
        ],
        "1": [
            "server_TCP_port",
            "502",
            "16",
            "190",
            false,
            "0195",
            "",
            ""
        ]
    },
    "extend": {}
}

Operation

Process Image

The modbus module relies heavily on its piControl submodule. It depends on piTest/piControlIf.h and the modules functions

  • piControlSetBitValue
  • piControlGetBitValue
  • piControlWrite
  • piControlRead
  • piControlWaitForEvent

The access is concentrated mostly within the file ComAndDataProcessor.c and lesser piProcessImageAccess.c, but there are also a few calls from piConfigParser/piConfigParser.c, piModbusServer.c, and piModbusClient.c which could and should be hidden away behind an interface.

Dependencies of piControl

Modbus protocol

The protocol is provided by libmodbus. The functions aren't accessed through a defined interface but forwarded by ComAndDataProcessor.h into two files (for now) and called directly. This causes issues with changes in libmodbus' API, apparently already an issue in the past and handled by the pre-processor via LIBMODBUS_VERSION_CHECK macro.

For each and every instance of a modbus device there is a new thread started within the Scheduler module. The full functionality like coils and holding registers currently are supported by the function processModbusAction from the ComAndDataProcessor module, which is used by the modbus client.

The server on the other hand is limited by the functionality of libmodbus mapping. libmodbus provides following types which could be used with client/server communication:

  • bits
  • input_bits
  • registers
  • input_registers

piConfigParser.c does only configure/read input and holding registers for the time being.