Command Flows — Step-by-Step Traces

Complete traces from UI button press to wire bytes. Each flow shows: what the user does → what the app validates → what bytes are sent → what response is expected.


Flow 1: Solarbank 2 Schedule (param_type 6)

User Action

Create custom schedule: Mon-Fri 00:00-08:00 at 200W, 08:00-24:00 at 600W

Call Chain

Energy Plan UI → A17C1AnkerDevice::setTacticsTime()
  → A17C1DeviceController::setTacticsTime() [14020 bytes, largest function!]
  AND
  → ElectricityUsageHelper → HTTP set_site_device_param

Dual Path: BLE + API (both sent)

API Path:

POST /power_service/v1/site/set_site_device_param
{
  "site_id": "<site_id>",
  "cmd": 246,
  "param_type": "6",
  "param_data": "{\"mode_type\":3,\"custom_rate_plan\":[{\"index\":0,\"week\":[0,1,2,3,4],\"ranges\":[{\"start_time\":\"00:00\",\"end_time\":\"08:00\",\"power\":200},{\"start_time\":\"08:00\",\"end_time\":\"24:00\",\"power\":600}]}]}"
}

Note: cmd = 246 (0xF6) for cloud, NOT 17 as in thomluther's API. Both values work — thomluther uses 17, APK uses 246.

BLE Path:

Command 0x005E with up to 30 TLV tags (a2-bb) + timestamp (fd)
MTU = 400 (larger than default 200 for schedule data)
CRC32 checksum appended as tag 0x1FA (506)

DischargeTimeModel (per time slot)

Bytes [0-1]: startTime (minutes from midnight, LE) — e.g., 0 = 00:00
Bytes [2-3]: endTime (minutes from midnight, LE) — e.g., 480 = 08:00
Bytes [4-5]: power (watts, LE) — e.g., 200
Bytes [6-7]: chargingPercentage (SOC target %)
Bytes [8-9]: weekday_mask (optional, 0 if absent)

Constraints

  • Maximum 14 time slots (from 14 buffer allocations)
  • Maximum 7 weekday groups (from 7 anonymous closures)
  • CRC32 checksum required on BLE path
  • Schedule enable condition: NOT (is_charge_priority AND secondary_flag)

Flow 2: EV Charger Start Charging

User Action

Tap "Start Charging" / "Start Now" / "Boost" button

ChargeControlType Values

Action controlType value UI Label
Start (scheduled) 1 "evChargeStart"
Stop / Cancel 2 "evChargeStop"
Start Now (immediate) 3 "evChargeStartNow"
Boost 4 "evChargeBoost"

Call Chain

A5190 Home Page → onTapControl(ChargeControlType)
  → AKIotEVChargeCommand::setControlType(controlType)
    → AKIotBasicCommand::writeProperty("action_control_charging", {"controlType": <int>})
      → IotManagerExtension → akiot.device.write_property (MQTT)

The Payload (simple!)

{
  "action": "action_control_charging",
  "params": {
    "controlType": 3
  }
}

encoding_type 2 — What We Found

Critical finding: encoding_type does NOT exist in the Flutter layer. The APK sends a standard action_control_charging via akiot.device.write_property.

The encoding_type: 2 differentiation (from thomluther's mqttcmdmap.py) happens below the Flutter layer — either in:

  • The AK IoT Kit native SDK (Android/iOS, not Dart)
  • The cloud MQTT broker
  • The device firmware

The Flutter app does NOT generate a random seed, does NOT handle special encoding. It simply sends {"controlType": 1/2/3/4} and the infrastructure handles the rest.

Error Handling

  • On failure: shows "evChargeStartFailedHint" toast
  • On boost success: shows BoostTipsToastUtil::showSuccessToast() + delayed callback
  • Duration tracked: start_time to end_time measured for telemetry

What This Means for Issue #322

The actual MQTT wire format with encoding_type 2 must be reverse-engineered from mqtt_monitor captures on a real EV Charger — the APK cannot reveal it. The controlType values (1-4) are confirmed and directly usable.


Flow 3: Smart Plug Countdown Timer (007e)

User Action

Set 30-minute timer to switch plug OFF when done

Call Chain

A17X8 Countdown Page → changeStartOrPause()
  → _isCurDeviceConnected() check (4 steps)
  → State toggle: idle(0) → running(6), running(6) → paused(4)
  → _setCountdownCmd()
    → A17X8DeviceController::setCountdownCmd()
      → sendCommandWithParam([0, 0x7E], valueMap)

Countdown States

Value State
0 Idle / no countdown
4 Paused
6 Running

TLV Command (0x007E)

For "30 min, switch OFF":

  • Total time: 1800 seconds = 0x000708
  • switchState: OFF = 0
  • type: Start = 6
Tag (thomluther) TLV Key Bytes Value Encoding
a2 0x0144 1 06 type: 6=start, 4=pause, 0=delete
a3 0x0146 3 08 07 00 totalTime: 1800s (LE)
a4 0x0148 1 00 switchState: 0=OFF, 1=ON
a5 0x014A 3 08 07 00 remainTime: 1800s (LE, same as total on start)

intToList3 Encoding (little-endian)

1800 decimal = 0x000708
→ [0x08, 0x07, 0x00]  (low byte first)

Delete Timer

Same command 0x007E with type = 0 (no separate delete opcode):

a2: 00  (type=delete)
a3: 08 07 00  (original total time)
a4: 00  (switch state)
a5: 00 00 00  (remain=0)

Pause Timer

Same command with type = 4:

a2: 04  (type=pause)
a3: 08 07 00  (original total time)
a4: 00  (switch state)
a5: DC 05 00  (remain=1500s = 25 min remaining, LE)

Resume Timer

Same command with type = 6 and updated remainTime.

Timer Status in 0405 (tag 0xAD)

Minimum 8 bytes:

Bytes [0-5]: totalTime via listToInt (e.g., 1800)
Byte  [6]:   switchState (0=OFF, 1=ON target)
Byte  [8]:   elapsed time marker
Computed:    remaining = max(0, totalTime - elapsed)

Stored at device offset 0x477 as CountDownInfo object. EventBus message 1356 fired on update.

Debounce

After relay toggle (007a), a delayed Future prevents re-toggling. No debounce on timer commands themselves.


Flow 4: Smart Plug Schedule (007c)

User Action

Create schedule: "Turn ON at 08:00, Turn OFF at 22:00, repeat Mon+Wed+Fri"

Call Chain

A17X8 Timing List Page → _setTimingCmd()
  → _isCurDeviceConnected() check
  → A17X8DeviceController::setTimingCmd(timingInfo)
    → sendCommandWithParam([0, 0x7C], valueMap)

TimingInfo Fields

Field Source Description
actionType UI action 0=delete, 1=create, 2=update
id slot index Schedule entry number
switchState target 0=OFF, 1=ON (but see inversion below!)
hours time picker Hour (0-23)
minutes time picker Minute (0-59)
isEffective toggle INVERTED Device test shows a4=1=enabled (normal, NOT inverted)
repeatCycleList weekday picker Day numbers: [1,3,5] = Mon,Wed,Fri

TLV Command (0x007C)

For "Create: ON at 08:00, Mon+Wed+Fri":

Tag (thomluther) TLV Key Bytes Value Encoding
a2 0x0144 1 01 actionType: 1=create
a3 0x0146 1 00 id: 0 (first slot)
a4 0x0148 1 01 switchState: 1=ON
a5 0x014A 1 00 minutes: 0
a6 0x014C 1 08 hours: 8
a7 0x014E var 01 03 05 weekdays: Mon(1), Wed(3), Fri(5)

isEffective Inversion CORRECTION (device-tested 2026-03-28)

APK assembly showed inverted logic, but device test disproves it:

  • All 3 commands (create/modify/delete) sent a4=1 for an enabled schedule
  • a4=1 = ENABLED (normal, not inverted)
  • The assembly inversion was UI-layer logic, not protocol-level

Weekday Encoding

  • Variable length list of day numbers
  • 1=Monday, 2=Tuesday, ... 7=Sunday
  • NOT a bitmask — sequential bytes, one per day
  • Only added to TLV if list is non-empty

Device-Tested Schedule CRUD (2026-03-28, A17X8)

3 mqtt_monitor runs: create → modify → delete. All tags verified:

Tag CREATE MODIFY DELETE Meaning
a2 1 2 0 action: 1=create, 2=modify, 0=delete
a3 1 1 1 slot_id (first slot)
a4 1 1 1 enabled (1=yes, NOT inverted)
a5 14:00 (20h) 15:00 (21h) 15:00 time (hour in sile, LE)
a6 1 1 1 switch: 1=ON
a7 01:02:05 01:02:05 01:02:05 weekdays: Mon+Tue+Fri
fe varies varies varies timestamp

Time encoding: hour as 2-byte sile (20 = 0x14:0x00, 21 = 0x15:0x00). Weekdays confirmed: sequential day numbers (NOT bitmask). 1=Mon, 2=Tue, 5=Fri.

Max Schedules

  • Default: 24 (from timing_limit device attribute)
  • Configurable per device via getDeviceAttrsInfo("timing_limit")

Delete Schedule

Same command 0x007C with actionType = 0:

a2: 00  (delete)
a3: 03  (id of schedule to delete)

Response Coupling

Timing query response also carries relay switch state:

"获取定时-----更新继电器开关状态" (get timer → update relay switch state)

Schedule and switch state are coupled in the protocol.


Flow 5: Solarbank Power Limit Change

User Action

Change power output from 400W to 800W

Call Chain (4 distinct paths!)

A17C1 Home Logic → guards check → A17C1AnkerDevice::setDevicePowerLimit()
  → A17C1DeviceController::setDevicePowerLimit()
    → sendCommandWithParam([0, 0x80], valueMap)

Guards (checked in order, any fail → skip)

# Check Field Consequence
1 Device online? offset 0x4CF Skip entirely
2 Value changed? offset 0x297 vs cached Skip if unchanged
3 fc_enabled? offset 0x28B Return null if true + no params
4 0W grid-collapse? offset 0x28F == 2 Show dialog

4 Code Paths

Path Condition Tags Sent
1 acPowerLimit provided a2+a4+a6+a8+aa+ac (full)
2 param2 provided, no acPower a2+a4+a6 (AC path)
3 pvPowerLimit provided a8+aa only (PV path)
4 ALL null (default) a8+aa only (checks fc_enabled first)

TLV Command (0x0080)

For "set output to 800W":

Tag (thomluther) TLV Key Bytes Value Encoding
a2 0x0144 2 feeder0w value intToList2 (LE)
a4 0x0146 2 00 00 (always 0) intToList2
a6 0x0148 2 acPowerLimit intToList2
a8 0x014A 2 switch0w value intToList2
aa 0x014C 2 pvPowerLimit intToList2
ac 0x014E 2 additional intToList2

After Sending

  • If charge_priority == 4 → sets is_charge_priority flag
  • If charge_priority == 2 → sets secondary charge priority flag
  • Both flags affect schedule enable status


Flow 6: Solarbank SOC Reserve Change

Call Chain

Settings Page → showSocPicker() (bottom sheet wheel picker)
  → requestToSetSoc()
    → STEP 1: API POST set_power_cutoff {device_sn, cutoff_data_id}
    → STEP 2 (on API success only): BLE 0x0067 {tag a2=currentSOC, a4=minSOC, a6=newSOC}
    → EventBus fire(2214, 2)

Key Details

  • SOC options come from server via get_power_cutoffpower_cutoff_data list
  • NOT set_site_device_param(param_type=18) — uses dedicated set_power_cutoff endpoint
  • API-first: BLE only sent on API success. If API fails → BLE never fires.
  • Default fallbacks: 10%, 5%, 10% (if server returns null)

Flow 7: Solarbank Toggle Grid Export (switch_0w)

Call Chain

Home Page onInit → getDeviceAttrs(["enable_0w", "switch_0w"]) reads current state
Setting change → setGridConnectedInput()
  → API POST set_device_attrs {device_sn, attributes: {switch_0w: <value>}}
Off-grid variant → BLE 0x0073 {tag a2 = 0 or 1}

Key Details

  • Grid export toggle goes through API (set_device_attrs), not BLE 0x0080
  • Off-grid switch uses separate BLE command 0x0073 (not 0x0080)
  • enable_0w = capability (can this device do 0W?), switch_0w = current setting
  • 11 attributes fetched in single batch for the power limit page

Flow 8: Solarbank Temperature Unit

Call Chain

Settings → showTempPicker() (bottom sheet: index 0=C, 1=F)
  → A17C1DeviceController::setTempUnit()
    → BLE 0x0050, payload = intToList(index)

Key Details

  • BLE only — no API call
  • Optimistic UI update (local state changed immediately, no wait for response)
  • Status reflected in tag a9 of 0405 status

Flow 9: Smart Plug Relay Toggle (007a)

Call Chain

Home Page → changeSwitch()
  → XOR toggle (flips boolean)
  → A17X8DeviceController::setRelaySwitchCmd()
    → BLE 0x007A {tag a2 = 0(OFF) or 1(ON)}
    → ALSO MQTT cloud path (dual: BLE + MQTT)
  → debounce: 2 seconds Future.delayed

Key Details

  • Dual path: BLE for direct, MQTT for cloud sync (both sent)
  • 2-second debounce after toggle (prevents rapid switching)
  • If relay turned ON → calls _clearFromGridCurve() (resets energy graph)

Flow 10: PPS AC Output Toggle (004a / varies)

Call Chain

PPS Home → AC toggle
  → A1770DeviceController::setAcSwitch()
    → BLE command (from A1770Commands::setAcSwitch static field)
    → payload: intToList(0=OFF, 1=ON)

Key Details

  • No explicit battery-low guard in AC switch
  • A1790 has dual routing: A17B1-style BLE vs standard ZX BLE (based on isA17B2 flag)
  • Status in parseSwitchData: index [18]=AC state, [20]=DC state, [24]=smart mode

Flow 11: A5101 HES Work Mode Change

Call Chain

System Policy Page → sendDeviceCommandOfTou() (or other mode method)
  → sendDeviceCommandOfMode(mode_int)
    → 3 guard checks (BLE object, connection data, field_83)
    → If online: sendDeviceCommondOfNetWork({mode: <int>}) → debounce → sendDeviceCommand
    → If BLE only: A5101BleLogic::setShiftMode(mode)

Mode Values

Value Mode Display Name
1 Time-of-Use "timeOfUse"
0x10 (16) AI EMS Special path with dismiss
0x14 (20) (another AI variant?) Triggers dismiss

Key Details

  • Mode change sends ONLY the mode — does NOT set peak_shaving or conserve_percent
  • Those are separate dedicated commands
  • Response includes electricity_strategy_mode + price_source_sub_type

Flow 12: A5101 HES Storm Guard

Manual Disaster BLE Payload

{"dpe":1,"dpn":[{"start":<start>,"end":<end>,"type":1,"soc":<soc>}]}

Disabled:

{"dpe":0,"dpn":[]}

Auto Disaster

  • Uses AutoDisasterMixin::request() via HTTP
  • Model: DisasterSetting with autoDisasterSwitch, manualDisasterSwitch, disasterEvents
  • Auto-disaster data synced to device via BLE in packets, enable/disable sent AFTER sync

Key Details

  • SOC reserve is user-configurable (no hardcoded default visible)
  • Manual and auto are independent — can have both configured

Flow 13: Site Price Configuration

API Endpoint

POST /power_service/v1/site/update_site_price

Fixed Price Payload

{
  "site_id": "<id>",
  "price": 0.30,
  "site_co2": 0.5,
  "site_price_unit": "EUR/kWh",
  "price_type": "fixed",
  "current_mode": null,
  "accuracy": 2
}

TOU / Dynamic Price Payload

Same endpoint, price_type = "use_time". Dynamic vs static TOU differentiated via price_source_sub_type in device command, not in site price API.

Key Details

  • accuracy defaults to 2 (decimal places)
  • price_type defaults to "fixed"
  • Most currencies use 5 decimal places, 2 specific markets use 4 (JPY/KRW?)
  • CO2 calculation is server-side only

Flow 14: A5101 Battery Reserve

Call Chain

System Policy Slider (0-100%) → sendDeviceCommandOfConservepercent(value)
  → If online: sendDeviceCommondOfNetWork({conserve_percent: <int>})
  → If BLE: A5101BleLogic::setBatteryReserve(value)

Key Details

  • Slider range: 0-100 (hardcoded in UI)
  • Display inversion: slider shows 100 - conserve_percent (100% slider = 0% reserve)
  • Fallback: 80% if value < 0 (safety default)
  • Default initial value: 20%

Complete Flow Summary

# Flow Command Path Key Insight
1 SB Schedule API type=6 + BLE 005e Dual cmd=246, CRC32, 14 max slots
2 EV Start action_control_charging MQTT only encoding_type 2 is below Flutter
3 Plug Timer BLE 007e BLE+MQTT States 0/4/6, delete=type 0
4 Plug Schedule BLE 007c BLE+MQTT a2=action(0/1/2), a7=weekdays, max 24. a4 NOT inverted (device-tested)
5 SB Power Limit BLE 0080 BLE 4 code paths, guards
6 SB SOC Reserve API set_power_cutoff + BLE 0067 API first NOT param_type 18!
7 SB Grid Export API set_device_attrs API BLE 0073 for off-grid variant
8 SB Temp Unit BLE 0050 BLE only No API, optimistic UI
9 Plug Toggle BLE 007a + MQTT Dual 2s debounce, clears energy graph
10 PPS AC Toggle BLE (varies) BLE Dual routing on A1790
11 HES Mode API sendDeviceCommand API/BLE Mode only, no side-effects
12 HES Storm Guard BLE JSON + API Both Manual: JSON, Auto: HTTP
13 Site Price API update_site_price API only accuracy=2, price_type="fixed" default
14 HES Battery Reserve API/BLE Both Slider inverted (100-value), default 20%